LVS-3625A 36 Volt 25 Amp Battery Charger Parts List
LVS-3625A 36 Volt 25 Amp Battery Charger Parts List
|
Part No.
| Description
| Qty
|
0090026218
| 115 Volt Power Cord 86"
| 1
|
| 0093026728 | Transformer 15.6V / 0.6 Amp | 1 |
0400700026
| SPDT Relay 12 Volt 30 Amp PanelMount
| 1
|
0499000121
| SPST Switch Lighted (16 Amp)
| 1
|
2299001902
| Cable Plug Set (8 Gauge)
| 1
|
2299002090
| Heat Sink Power Board INC /LSV-36
| 1
|
3599000200
| Battery Charger Handle
| 1
|
3999000127
| Blade Fuse 40 Amp 58 Volts
| 1
|
4999000078
| Cooling Fan 12 Volt DC
| 1
|
| LVS-3625A Troubleshooting Guide |
| PROBLEM | POSSIBLE CAUSE | SOLUTION |
| The charger is making an audible clicking sound. | Circuit breaker is cycling. | The settings may be wrong. Check the charger settings. |
| Battery is defective. | Have the battery checked. |
| Shorted battery cables or connector. | Circuit breaker cycles when current draw is too high. Check for shorted cables or connector and replace if necessary. |
| Severely discharged battery, but otherwise it is a good battery. | The battery may not want to accept a charge due to a run-down state. Allow charging to continue until battery has a chance to recover sufficiently to take a charge. If more than 20 minutes, stop charging and have the battery checked. |
| Reverse connections at battery. | Shut the charger off and correct the lead connections. |
| Charger makes a loud buzz or hum. | Transformer laminations vibrate (buzz). | No problem, this is a normal condition. |
| Shorted Diode Assembly or Output Rectifier Assembly (hum). | Have charger checked by a qualified technician. |
| CHARGING (yellow) LED is blinking. | Indicates the charger is in abort mode. | See “Abort Mode” in the OPERATING INSTRUCTIONS Section. |
| The battery is connected and the charger is on, but is not charging. | Connector is not making a good connection. | Check for poor connection at battery. Make sure connecting points are clean. Rock connector back and forth for a better connection. |
| The measured current is much lower than what was selected. | The charger reached the maximum voltage and is reducing the current. | No problem, this is a normal condition. |
|
When a charging problem arises, make certain that the battery is capable of accepting a normal charge. Double check all connections, AC outlet for a full 120-volts, charger clips for correct polarity and the quality of the connections from the cables to the clips and from the clips to the battery system. The clips must be clean.
When a battery is very cold, partially charged or sulfated, it will not draw the full rated amperes from the charger. It is both dangerous and damaging to a battery to force higher amperage into it than it can effectively use in recharging.
*Variations of models due to production changes and parts availability are not our responsibility*No refunds on electrical components*Service should be performed only by a qualified technician*Please read all supporting documentation and safety instructions