114748 Robinair Hose Gaskets For 1/4 And 1/2 ACME Hoses (Each)
|
|

These gaskets fit 1/4" flare and 1/2 ACME standard hose fittings. If you are doing maintenance on you unit it's a good idea to replace these as well as they become crushed over time resulting in poor flow or restriction due to swelling. These are standard for some other vendors hoses as well.
|
|
 |
|
|
|
|
 |
17506 Robinair 50lb. 1/4 Flare Refillable Refrigerant Tank
|
|

50lb. R-12 / Universal Gas Refillable Refrigerant Tank. Red Vapor Blue Liquid Ported Valve. 50 lb. capacity refrigerant tank for R-12, R-22, R-502 (universal) with 1/4" Flare fittings
|
|
 |
|
|
|
|
 |
19225 Robinair Float Switch Cable
|
|

Float Switch Cable Makes the connection between the float in the tank and the system relay. When the tank reaches 80% capacity, the float interrupts the control voltage to the system relay causing the unit to shut down.
|
|
 |
|
|
|
|
 |
19497 Robinair Optional 80% Overfill Float Cable Relay Kit 115v
|
|

Optional Float Cable and Relay assembly for Portable Recovery Units: 25200B 25175A 25150A. Enables recovery units to operate with 80% float tanks. This item has been discontinued, see 19225 Cable & RA19133 relay as replacements.
|
|
 |
|
|
|
|
 |
19651 Robinair Rebuild Kit For 19652 DC Oil-Less Compressor
|
|

Rebuild Kit For 110 Dc Oil-Less Compressor
|
|
 |
|
|
|
|
 |
19652 Robinair Oil-Less Compressor For 25150A 25175A 25200B 17800B
|
|

19652 Robinair Oil-Less Compressor For 25150A 25175A 25200B 17800B (Special order item)
|
|
 |
|
|
|
|
 |
19666 Robinair Low Side Gauge For 25175a 25200b
|
|

Low Side Gauge For 25175a / 25200b
|
|
 |
|
|
|
|
 |
19667 Robinair High Side Gauge For 25200b
|
|

High Side Gauge For 25200b
|
|
 |
|
|
|
|
 |
19685 Robinair Float Chamber For 25200B 25201B 25202B
|
|

19685 Robinair Float Chamber For 25200B 25201B 25202B
|
|
 |
|
|
|
|
 |
19686 Robinair Manifold Assembly For 25200b 25202b
|
|

Manifold Assembly For 25200b / 25202b
|
|
 |
|
|
|
|
 |
19808 Robinair Spool Valve 25XXX Series Units
|
|

Spool Valve 25XXX Series Units
|
|
 |
|
|
|
|
 |
19813 Robinair Robinair Switch Recover Self Clear
|
|

Robinair Switch Recover / Self Clear
|
|
 |
|
|
|
|
 |
25200B Robinair Multi Refrigerant Recovery Unit
|
|

Multi Refrigerant Recovery Unit, ultra fast "Liquid Lift" technology moves liquid faster than virtually any unit in its class. Designed for recovery of medium and high-pressure refrigerants, including R-410A, automatically switches from liquid to vapor recovery, provides continuous recovery without the need to change the hose or flip a switch.
Published Recovery Rates |
Direct Liquid - 7.0 lb/min |
Direct Vapor - 0.4 lb/min |
Push/Pull - 7 lb/min |
|
|
 |
|
|
|
|
 |
40083 Robinair Gaskets For 1/4 & ACME Charging Hoses (Pkg. Of 6)
|
|

These gaskets fit 1/4" flare and 1/2 ACME standard fittings. If you are doing maintenance on you unit it's a good idea to replace these as well as they become smashed over time resulting in poor flow.
|
|
 |
|
|
|
|
 |
569104 Robinair Main Power Switch
|
|

Main Power Switch Controls the power between the power cord and the main board.
|
|
 |
|
|
|
|
 |
CRXTOSP1 CPS 3 Pin Brad Harrison Tank Overfill Cable Shorting Plug
|
|

CRXTOSP1 Tank Overfill Protection Cable Shorting Plug allows the user to override the tank float safety device on most recovery units using a 3 pin brad Harrison cable. Screws in place at the cable end allowing the unit to start. (Always use a scale for accuracy when using this device) 30 & 50 pound tanks should never be filled to a level beyond 80% of tank capacity.
|
|
 |
|
|
|
|
 |
NB6501 PROMAX 1/4" Flare Cap & Strap
|
|

1/4 Flare Seal Cap with anchor retention strap prevents loss when not in use.
|
|
 |
|
|
|
|
 |
RA17106 Robinair Red Light
|
|

Red Light High Pressure Light / Tank Full Light - Indicates when the discharge pressure reaches 350 psi or when the recovery tank is full.
|
|
 |
|
|
|
|
 |
RA17107 Robinair Amber Light
|
|

Amber Light Compressor ON Light/Recycling ON Light - Shows when power is being supplied to the compressor.
|
|
 |
|
|
|
|
 |
RA17416 Robinair Fan
|
|

Fan Used to keep the unit hermetic compressor and electrical components cool.
|
|
 |
|
|
|
|
 |
RA19133 Robinair Float Relay 115 Volt
|
|

Float Relay Interrupts power from the system relay. The Tank Full light comes on when the float opens the circuit.
|
|
 |
|
|
|
|
 |
RA19288 Robinair Manifold Bypass Check Valve
|
|

Manifold Bypass Check Valve Prevents flow to the manifold bypass solenoid during the recovery, recycling, and charging modes.
|
|
 |
|
|
|
|
 |
RA19343 Robinair Main Power Switch
|
|

Main Power Switch Controls the power between the power cord and the main board.
|
|
 |
|
|
|
|
 |
RA19804 Robinair Float Chamber 17800B Series
|
|

Float Chamber 17800B Magnetic float switch that sends a signal to the main circuit board when liquid is entering the system. The RA19804 Series bottle switch is a compact, economical liquid level sensing device for external mounting in applications not suited to small, internally-mounted level switches. These single point devices are typically used for low or high level sensing. 1/4" NPT Inlet (Bottle) 1/8" NPT Outlet (Cap).
|
|
 |