|
|
|
|
Phantoms. Gremlins. Glitches. Ghosts in the Machine. We all have names for them; those hard-to-find problems that seem to randomly appear, then disappear. The new inGEN® Diagnostic Data Recorder from Midtronics will help you locate and identify electrical system problems once and for all. After installation in your customer’s vehicle, it becomes a continuous diagnostic monitoring tool that captures and records all electrical system activity; even intermittent errors. You can then analyze the data and quickly locate, diagnose, and correct the problem; eliminating frustrating guesswork and customer returns.
Measurement Specifications |
|
Current Consumption (approximate): FULL POWER MODE: 150 mA LOW POWER MODE: 20 mA (with auxiliary current disabled) DEEP SLEEP MODE: less than 5 mA
Current Measurements: Main: -350 A to 350 A, 0 A to 7.5 A*, +/- 20 mA, 100 A to 350 A*, +/- 1 A Charge and discharge current Aux: -30 to 30 A max (fused), +/- 40 mA, connected in line with vehicle fuse
Voltage Measurements: Main: 9 to 16 Vdc, +/- 20 mV Aux 1: On / off with settable threshold (triggerable) Aux 2: On / off with settable threshold Aux 3: On / off with settable threshold Aux 4: On / off with settable threshold
Temperature Sensor: Located in DDR housing to approximate battery temperature. Measurement range: -4F to 158F (-20C to 70C)
Operating Voltage: 7 to 16 Vdc
|
|
Physical Specifications |
|
Display: 2-line, 16-Character LCD Display Updates every 2 seconds with live data
Length: 9 (22.86 cm)
Width: 3.875 (9.84 cm)
Height: 1.5 (3.81 cm)
Weight: 1.6 lb (703 g)
Operating Temperature: -4F to 158F -20C to 70C | |
|
Data Recording Specifications |
|
Full Power Mode: Data is sampled at 50 ms, updates to data card a 30 second average of 50 ms samples every 30 seconds.
Low Power Mode: Data is recorded every 30 seconds. Check for current and voltage triggers every 1 second.
Deep Sleep Mode: Data is recorded every 5 minutes. Check for current and voltage triggers every minute.
Triggerable: In Full Power mode: Store 60 seconds of data centered on the trigger event at 50 ms intervals. In other modes: Store 60 seconds of data after the trigger event.
Triggers are set in DAS PC software and loaded into DDR with data card prior to installation in vehicle.
Triggerable Channels: Main Current Measurement Aux Voltage Channel 1 | |
Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
|
|
|
|
|