• Great New Tools. Low Sale Prices.

You are here: Home > Repair Parts > Refrigerant Recovery Parts > CPS Recovery Recycling Equipment Parts > AR2788S CPS R-134a Refrigerant Recovery Recycling Unit Parts

AR2788S CPS R-134a Refrigerant Recovery Recycling Unit Parts

ITEMDESCRIPTION

39-0206" 115 VOLT FAN
54-100OIL INJECTION BOTTLE
AR2788SX1AR2788S LOW BLOCK ASSYS/N PRIOR10/12 27AR001801
AR2788SX10AR2788S BLUE LOWSIDE SERVICE HOSES/N PRIOR10/12 27AR001801
AR2788SX11LIQUID TANK TO FILTER IN HOSE ASSY
AR2788SX12AR2788S VAPOR TANK HOSE W/ BALL VALVE S/N PRIOR10\12 27AR001801
AR2788SX13AR2788S DISCHARGE FILER HOSE W/ H ASSYS/N PRIOR10\12 27AR001801
AR2788SX17BLACK SCALE PATCH CORD
AR2788SX18RED RELAY PCB PATCH CORD
AR2788SX19YELLOW LOW SIDE BLOCK PCB PATCH CORD
AR2788SX2AR2788S HIGH BLOCK ASSY
AR2788SX20GREEN HIGH SIDE BLOCK PCB PATCH CORD
AR2788SX21AR2788S LOW SIDE BLOCK PCB
AR2788SX22AR2788S HIGH SIDE BLOCK PCB
AR2788SX23AR2788S MAIN PCB
AR2788SX24LCD PCB
AR2788SX253 RELAY PCBS/N PRIOR 10/12 27AR001801
AR2788SX26TANK TEMP SENSOR OIL SEPARATORS/N PRIOR10/12 27AR001801
AR2788SX27TEMPERATURE SENSOR AMBIENT MAIN PCBS/N PRIOR10/12 27AR001801
AR2788SX28OIL INJECTION ASSY
AR2788SX29TANK FILTER BRACKET/STRAPS
AR2788SX3SCALE MODULE
AR2788SX30OIL DRAIN BOTTLE
AR2788SX34ON-OFF MOMENTARY SWITCH
AR2788SX35OIL DRAIN TO BULK HEAD HOSE S/N BEYOND10\12 27AR001802
AR2788SX36FILTER OUT TO BULK HEAD LIQUID FITTING HOSES/N BEYOND 10/12 27AE001802
AR2788SX37LS1 WITH BULK HEAD LIQUID FITTING HOSES/N BEYOND10/12 27AR001802
AR2788SX38HV1 w/BULK HEAD VAPOR FITTING HOSES/N BEYOND10/12 27AR001802
AR2788SX39COMPRESSOR OIL SUMP TO HV3 HOSES/N BEYOND10/12 27AR001802
AR2788SX4AR2788S/AR2700 COMPRESSOR ASSY 115V
AR2788SX40OIL SEPARATOR DRAIN-HV2 HOSES/N BEYOND10/12 27AR001802
AR2788SX41HV2-COMPRESSOR S2 HOSES/N BEYOND10/12 27AR001802
AR2788SX42COMP DISCHARGE TO OIL SEPARATOR IN HOSES/N BEYOND10\12 27AR001802
AR2788SX7REGULATOR SET 50 PSI
AR2788SX9AR2788S RED HIGH SIDE SERVICE HOSES/N PRIOR10/12 27AR001801
AR2788X14A1/2 ACME REFILL HOSE
AR2788X14B1/4 SAE REFILL HOSE
AR2788X16LOW SIDE GAUGE KIT
AR2788X17HIGH SIDE GAUGE KIT
AR2788X18LOW SIDE CHARGE ADAPTER
AR2788X25SCALE PCB
AR2788X28POWER SUPPLY PCB
AR2788X301 LB CHECK WEIGHT
AR2788X3215 AMP BREAKER 115 VAC
AR2788X35KEY PAD
AR2788X406 FT POWER CORD 115 VAC
AR2788X45HIGH PRESSURE SWITCH 450PSI
AR2788X46PRESSURE TRANSDUCER
AR2788X53IEC HEATER BLANKET/VAC PUMP OUTLET
AR2788X571/8 GAUGE TUBE/WITH COMPRESSION FITTINGS
AR2788X64CASTOR W/BRAKE
AR2788X6510" WHEEL
AR27XHB115115 VAC HEATER BLANKET
AR27XHB115115 VOLT 300 WATT HEATER BLANKET
ARXF5RECYCLING FILTER
CRX400T50 LB TANK
CRX400T90 LB TANK
FA1234X10134A LOW SIDE SERVICE HOSES/N BEYOND10/12 27AR001802
FA1234X13DISCHARGE TO TANK VALVE HOSE VAPORS/N BEYOND10/12 27AR001802
FA1234X14134A FILTER TO LIQUID H ASSY HOSES/N BEYOND10/12 27AR001802
FA1234X16VAC PUMP HOSES/N BEYOND10/12 27AR001802
FA1234X284 RELAY PCBS/N BEYOND10/12 27AR001802
FA1234X29TEMP SENSOR INTERNAL TANK VAPOR LINES/N BEYOND10/12 27AR001802
FA1234X30TEMP SENSOR AMBIENTS/N BEYOND10/12 27AR001802
FA1234X34134A COUPLER STORAGE FITTINGS SET S/N BEYOND10/12 27AR001802
FA1234X39IEC INLET, SCREW MOUNT
FA1234X5FA1234 OIL DRAIN BOTTLE ASSEMBLYS/N BEYOND10/12 27AR001802
FA1234X6LOW BLOCK COMPLETE S/N BEYOND10/12 27AR001802
FA1234X9134A HIGH SIDE SERVICE HOSES/N BEYOND10/12 27AR001802
QCH134134A HIGH SIDE SERVICE COUPLER
QCL134134A LOW SIDE SERVICE COUPLER
VP6DVACUUM PUMP 6 CFM 2 STAGE
VPXF15VACUUM PUMP FUSE
VPXODPVACUUM PUMP OIL DRAIN PLUG
VPXOMPVACUUM PUMP EXHAUST CAP

Filters

Filters

Sort By:
Products per page
TROUBLESHOOTING
ProblemHigh Pressure Limit.
SolutionCheck that both Storage Tank valves are open. Check that any inline hose ball valves to the Storage Tank are open.
ProblemTank Overfill.
SolutionRemove refrigerant from Storage Tank by charging into an empty refrigerant cylinder. If this does not fix the problem, then Re-Zero scale.
ProblemUnit not Charging accurately.
SolutionMake sure Storage Tank is properly placed on platform so that no portion of the tank is touching the back of the unit or protective frame work of the unit.
SolutionDo not move the unit while in the charging mode. The unit utilizes a weighing method of charging. Sudden movement of the storage tank will affect the charging accuracy.
SolutionMake sure unit is on a level surface. If placed on surface with more than 2% grade, the charging amount may be incorrect.
ProblemUnit will not power up.
SolutionCheck to make sure power switch on the back of unit is ON.
SolutionCheck to make sure circuit breaker on back of unit is not tripped. Reset and restart the unit if necessary.
SolutionPush the battery reset button on the back of the unit.
SolutionMake sure power cord is plugged into the back of the unit and the wall receptacle.
ProblemUpon compressor start up, the circuit breaker trips.
SolutionReset circuit breaker and try again.
ProblemUpon vacuum pump start up, the circuit breaker trips.
SolutionCheck Oil Level in vacuum pump. Reset circuit breaker and try again.
SolutionMake sure vacuum pump voltage switch is in the correct position.
Empty Cart