Product Features
-
Detects: All CFC, HFC, and HCFC Refrigerants
-
Sensing Element: Positive Ion Emission Heated Diode
-
Sensitivity: Moving probe test per SAE Std. J1627
Alarm Sensitivity:
R-134a
Moving Probe
-
Small - 0.5 oz/year
-
Medium - 1.0 oz/year
-
Large - 5.0 oz/year
Stationary Probe
-
Small - 0.1 oz/year
-
Medium - 0.5 oz/year
-
Large - 2.0 oz/year
R-12
- Small - 0.1 oz/year
- Medium - 0.5 oz/year
- Large - 3.0 oz/year
Warm-Up Time: Approx. 2 minutes
Accuracy: Exceeds SAE J1627
Probe Length: 4.5 feet
Dimensions: 2.5" x 4.5" x 8.5"
Weight: Approx. 3 lbs
Agency Listings: UL file SA9717, SAE J1627, CE-Mark
Power: 120 VAC, 50/60 Hz (optional 220/230/240 VAC)
Leak Alarm: Audible alarm and visible neon lamp
Response Time: Approx. 1 sec.
|