- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- Maximum voltage between any terminal and earth ground: 600V
- Surge Protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
- Display: Digital - 6,000 counts, updates 4 per second
- Bar Graph: 33 segments, updates 32 per
- CAT III 600 V safety rated
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
Model includes the following:
- Holster
- Installed 9 V battery
- 4 mm silicone test lead set
- User manual
| Specifications |
| Maximum voltage between any terminal and earth ground | |
| Surge protection | | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
| Display | | Digital: | 6,000 counts, updates 4 per second |
|
| Bar graph | | 33 segments, updates 32 per second |
|
| Operating Temperature | |
| Storage Temperature | |
| Battery type | | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life | | 400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts | | Range: | 600.0 mV | | Resolution: | 0.1 mV | | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts | | Range/Resolution: | 6.000 V / 0.001 V | | Range/Resolution: | 60.00 V / 0.01 V | | Range/Resolution: | 600.00 V / 0.1 V | | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
| AC millivolts1 true-rms | | Range: | 600.0 mV | | Resolution: | 0.1 mV | | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms | | Range/Resolution: | 6.000 V / 0.001 V | | Range/Resolution: | 60.00 V / 0.01 V | | Range/Resolution: | 600.0 V / 0.1 V | | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity | | Range: | 600 Ω | | Resolution: | 1 Ω | | Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
| Ohms | | Range/Resolution: | 600.0 Ω / 0.1 Ω | | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | | Accuracy: | 0.9 % + 1 | | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | | Accuracy: | 5 % + 2 |
|
| Diode Test | | Range/Resolution: | 2.00 V / 0.001 V | | Accuracy: | 0.9% + 2 |
|
| Capacitance | | Range/Resolution: | 1000 nF / 1 nF | | Range/Resolution: | 10.00 µF / 0.01 µF | | Range/Resolution: | 100.0 µF / 0.1 µF | | Range/Resolution: | 9999 µF / 1 µF | | Range/Resolution: | 100 µF to 1000 µF | | Accuracy: | 1.9% + 2 | | Range/Resolution: | > 1000 µF | | Accuracy: | 5% + 20% |
|
| Lo-Z Capacitance | | Range: | 1 nF to 500 µF | | Accuracy: | 10% + 2 typical |
|
| AC amps true-rms (45 Hz to 500Hz) | | Range/Resolution: | 6.000 A / 0.001 A | | Range/Resolution: | 10.00 A / 0.01 A | | Accuracy: | 1.5% + 3 | | 20 A overload for 30-seconds max |
|
| DC amps | | Range/Resolution: | 6.000 A / 0.001 A | | Range/Resolution: | 10.00 A / 0.01 A | | Accuracy: | 1.0% + 3 | | 20 A overload for 30-seconds max |
|
| Hz (V or A input)2 | | Range/Resolution: | 99.99 Hz / 0.01 Hz | | Range/Resolution: | 999.9 Hz / 0.01 Hz | | Range/Resolution: | 9.999 kHz / 0.001 kHz | | Range/Resolution: | 50 kHz / 0.01 kHz | | Accuracy: | 0.1% + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range.
Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
| Mechanical & General Specifications |
| Size | | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
|
| Weight | |
| Warranty | |