The purpose of this SAE Standard is to provide minimum performance and operating feature requirements for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate AHRI 700 Standard or allow for on-site recycling of the recovered refrigerant to SAE J2788 specifications by using SAE J2788 or SAE J3030 -certified equipment. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system with this equipment be directly returned to a mobile A/C system. An identifier certified to SAE J2912 is to be used to identify the contents of the system prior to recovery of the refrigerant.
This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC- 134a (R-134a) A/C systems.
Improved refrigerant recovery equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Therefore, this standards supercedes, SAE J1732
SPECIFICATIONS
Model Number
TR21O
Compressor Type
2 Cylinder Oil-less Reciprocating Compressor
Dimensions
6" (15cm) Wide x 12" (30cm ) Long x 9" (23cm) High
Weight
23.0 lbs / 10.5 kg
Operating Temperature
32°F (0°C) to 120°F (49°C)
Power Source
Power Consumption
850 W
Filtration
Cleanable 100-mesh screen integrated into Suction Port
Overload Protection
Motor Thermally Protected
Refrigerants
R-12, R-134a, R-22, R-401A, R-401B, R-401C, R-402A, R-402B, R-404A, R-406A, R-407A, R-407B, R-407C, R-407D, R408A, R-409A, R-410A R-411A, R-411B, R-412A, R-500, R-502, R-507, R-509
Flow Rate @ 60Hz, reduce 15% for 50Hz
Direct Vapor
Up to 2.5 lb / min (Up to 67 kg / hr)
Direct Liquid
Up to 10 lb / min (Up to 271 kg / hr)
Push-Pull Liquid
Up to 34 lb / min (Up to 922 kg / hr)