Mastercool 99972 4-Way Digital Manifold with 3-72" (Blue, Yellow, Red)(1/4" SAE) Manual Ball Valve Hoses, 1-72" (Black)(3/8") Vacuum Hose, Vacuum Sensor with Cable, Clamp-On Thermocouple, Data Logger Software and USB Cable has the ability to Record and store up to 24 hours of data or 15 jobs, Over 60 Refrigerants, Displays Pressures, Saturated, Actual, Superheat and Subcool Temperatures, Clamp-on Thermocouple Connector displays Actual Temperature and Automatically Calculates Superheat or Subcool Temperature, Vacuum Sensor Cable displays Deep Vacuum, Ball valve design includes 3/8” bore through the block for increased flow. Manifold Only. Hoses and accessories are NOT Included with this item.
Easily Update Refrigerants: New refrigerants can be updated with a USB connection and Mastercool Software Includes 63 Refrigerants: R11, R12, R13, R21, R22, R23, R32, R113, R114, R115, R116, R123, R124, R125, R134, R134a, R141B, R142B, R143, R143A, R152A, R176, R218, R290, R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R408A, R409A, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R417A (ISCEON MO59), R422A (ISCEON MO79), R422D (ISCEON MO29), R427A (FX100), R501, R502, R503, R504, R507A, R508B, R509A, R600, R600A, R601, R601A
SPECIFICATIONS:- Pressure Display: PSI, INHg, Bar, MPa, Kg/cm2
- Temperature Display: °F or °C
- Deep Vacuum Display: Micron, mBar, KPa, Pa, Torr, mTorr, mmHg
- Sensing Resolution: 1 psi(.07 Bar, .007 MPa, .07 Kg/cm2)
- Sensing Accuracy: ±1 psi or 1% of reading (whichever is greater)
- Working Pressure: 0 to 750 psi (52 Bar, 5 MPa, 52 Kg/cm2)
- Proof Pressure: 1000 psi (70 Bar, 7 MPa, 70 Kg/cm2) (Tolerable pressure w/o internal damage)
- Refrigerant Temperature Range: -40 to 200°F (-40 to 93°C)
- Operating Temperature: 32 to 122°F (0 to 45°C)
- Temperature Accuracy: ±1˚F (±0.5˚C) between 32 to 160˚F (0 to 71˚C
- Storage Temperature: 10 to 120˚F (-12 to 49˚C)
- Connections: 1/4” M-Flare
- Power: 9V DC battery with optional AC/DC adapter
- Battery Life: 30-36 hours pressure and temperature mode only (continuous use) 25-30 hours vacuum and backlight mode (continuous use)
- Auto-Off: 15 min. with disabling capability
Easily Update Refrigerants:New refrigerants can be updated with a USB connection and Mastercool Software. Includes 63 Refrigerants: R11, R12, R13, R21, R22, R23, R32, R113, R114, R115, R116, R123, R124, R125, R134, R134a, R141B, R142B, R143, R143A, R152A, R176, R218, R290, R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R408A, R409A, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R417A (ISCEON MO59), R422A (ISCEON MO79), R422D (ISCEON MO29), R427A (FX100), R501, R502, R503, R504, R507A, R508B, R509A, R600, R600A, R601, R601A
 Warning: This product may expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product Features
- Digital 4-Way Manifold
- Set of Three 72" (Blue, Yellow, Red) Manual Ball Valve Hoses (1/4" SAE)
- One 72" (Black) Vacuum Hose (3/8")
- Vacuum Sensor with Cable
- Clamp-On Thermocouple
- Data Logger Software
- USB Cable
- In a Plastic Storage / Transport Case
- New refrigerants can be updated with a USB connection and Mastercool Software
Mastercool’s 4-Way Digital Manifold Recording Function: - Records and stores data directly into the manifold memory
- Records up to 24 hours of data or 15 jobs before having to download
- Downloads data at a rate 115 kb per second (24 hrs of data = approx. 15 min of download time)
- Uses Mastercool’s Data Logger Application to easily view data
Mastercool Data Logger Application- Display data in “real time” using a USB connection, computer and software
- Platform: Windows 2000, XP, Windows Vista and Windows 7
- Log Customer Name, Date and Technician’s Name
- Recorder/Cursor Function Features
- (1) Recorder TIME command. Record in intervals of 5, 15 min, 1, 4, 8 and 24 hrs
- (2) Recorder ON/OFF command
- (3) ZOOM: NORMAL, 5X or 10X. Use the zoom option to view specific data points of interest
- (4) The Time-Line measures the selected recording time. Moving the cursor along the timeline easily displays specific plot points
- The Data Logger program uses the Units information contained in each data bit on the manifold and displays these units on the screen
- Display Function Features
- (1) Display ALL command. This enables all parameters of the Digital Manifold to be displayed simultaneously. As the line functions propagate across the screen, the “real-time” data will also be displayed digitally
- (2) Monitor specific functions of interest. The Data Logger continues to record all the functions in the background, regardless of how many individual functions are being displayed
- (3) Display DEEP VACUUM ONLY command. This enables only the deep vacuum readings to be displayed on the screen
- (4) View ANALOG GAUGES function enables the user to represent the Digital Manifold data in the form of high and low pressure analog gauges
|
|
 |
 |
 |
 |

|