View CartMy Account / Order StatusHelp

Can't Decide what to get them? Send a gift certificate instead



Join our mailing list!



(Your shopping cart is empty)

  Home > Battery Charging Equipment > Battery Charger - Reconditioners >

  VEC1089A Vector 15/10/2 Amp Automatic 12 Volt Smart Battery Charger/Conditioner
  VEC1089A Vector 15/10/2 Amp Automatic 12 Volt Smart Battery Charger/Conditioner
 
Price $59.45


Product Code: VEC1089A
Qty:


Description
 
The Vector 1089A High Frequency Pulse Charge 12 Volt Fully Automatic Float Mode Monitoring Battery Charger. Patented State-of-the-art microprocessor technology charges batteries up to two times faster than conventional linear chargers. Automatic/high-frequency Smart™ Battery Charger with 3-stage automatic rapid charging — 3.5 minutes charge to start. Uses high-frequency power conversion technology and digital smart control. 5-year limited warranty. Exclusive digital LED display keeps the user informed of the battery's condition and diagnostic fault codes, through each charging stage.

This is not your Fathers Battery Charger
 
Product Features
Vector Smart Charger
  • 3 minute charge to start (Bulk Charge/Rapid Start)
  • 15/10/2 Amp Automatic 12 Volt Battery Charging
  • Battery type selection Ideal for Deep Cycle, AGM and Gel Batteries (It Does Them All)
  • Fully Automatic, leave it connected it won't overcharge
  • Built-in battery reconditioning (Desulfate) Extends Battery Life
  • Battery Cell Equalization
  • High frequency power conversion pulse technology
  • Digital diagnostics Mode spots problems in advance and prevents break downs and faults that cause damage
  • Alternator output and battery voltage check
  • Automatic Temperature Compensation
  • Spark resistant reverse polarity and short circuit protection
  • Reverse polarity indicator
  • Does Them All, Cars, Trucks, Farm Equipment, Marine, RV, Deep Cycle, Motor Cycle and Watercraft
  • Digital display shows charge rate, operating mode, fault codes, battery voltage and when battery is fully charged
  • 3 stage high frequency switch mode automatic rapid charging
  • Lightweight, high efficiency design
  • Internal short circuit protection
  • Cables and clamps self-stored
  • Microprocessor control (Digital Smart Control)
  • Compensates for low AC from extension cord use
1 Minute - Charge To Start

DIGITAL DIAGNOSTIC & FAULT CODE DISPLAY
Exclusive Digital LED Display shows Amps and various Diagnostic Battery Fault Codes
to determine actual battery condition.

OPERATION CODES

   
 
AC Power Indicator
Battery Reconditioning
Alternator
Voltage Check
Charger Standby
Battery Fully
Charged
 
   

FAULT CODES

   
   
 
Internal Shorted Cell
Battery - Replace.
Excessive Load - Check load.
Bad Battery Connection
Voltage Too Low To
Accept Charge - Replace.
Internal Open Cell -Replace. Sulfated Condition - Recondition
or replace
.
Overtime Condition -
Replace. Rate Is Set
Too Low - Set to
higher rate.
Overheated Condition - Disconnect and cool
for 30 minutes.
 



BATTERY CHARGERS


Vector’s PURE DC output current provides a more efficient, stable charge by regulating both voltage and amperage through each stage of the charging process, depending on the battery’s state of charge. This results in higher quality charge without overcharging or overheating of the battery while extending its serviceable life. Conventional chargers start out at their maximum rated current and steadily decline. Some models never shut off and can even “cook” a battery, resulting in excessive high temperature “boiling”, higher temperature which may lead to exposed plates and shorten the life of the battery.

Vector’s Smart Battery Chargers’ PURE DC output current provides a more high efficient charge. The crude form, chopped, pulsating DC current from conventional chargers produces a less efficient charge. Low AC line voltage and/or extension cord use can cause conventional chargers to produce a lower charging current that falls below rated specifications. Under these same conditions Vector’s Smart Battery Chargers’ output remains unaffected and charging current maintains itself at the full selected rate.

NEW SUPERIOR “SMART” 3-STAGE HIGH EFFICIENCY CHARGING TECHNOLOGY
Built-in Microprocessor Control Provides Fast, Safe and Full Battery Charge.

STAGE 1 - BULK CHARGE/RAPID START - More efficient than conventional type chargers, even in very hot or very cold temperatures, this charger delivers maximum charging amperage to “wake up” any serviceable 12 volt battery and allows for quick engine starting within minutes (see selection guide). When battery reaches a maximum safe predetermined voltage, the digital sensors and microprocessor automatically switch into stage 2 of the charging process.

STAGE 2 - ABSORPTION CHARGE - Maintains the maximum possible safe charge at a constant predetermined voltage. During this (stage 2) voltage absorption regulation charge, the charging voltage remains constant, while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer.

STAGE 3 - TOP-OFF CHARGE - Automatically maintains and reduces voltage to a predetermined level while adjusting current is adjusted for a safe, effective full battery charge (step-down regulation mode). Ideal for topping off batteries that have been in storage. Automatic shut-off occurs at full charge - you can trust this charger to never overcharge any battery, or cause pressure leaking of battery acid, even if it is left unattended while charging in hot summer temperatures.

BATTERY RECONDITION/DESULFATE New electronic pulse technology reverses the natural insulating sulfate build-up (commonly known as memory) on battery plates, significantly improving the charge carrying capability. Hook-up the charger, push the RECONDITION button and the rest is automatic. Shorted or open cells will not be fixed.

ALTERNATOR VOLTAGE CHECK can determine if the alternator is outputting within typical voltage range. NOTE: Alternators and electrical systems vary widely, so the accuracy of some indications are subject to test conditions, procedures and possible problems, as fully described in the User’s Guide. After a vehicle engine warm-up period of ten minutes, the test takes five seconds. An Alternator Good LED lights if the alternator is within typical range.


* Approximate charging times are based on 50% discharged mid-size car battery.
** Approximate charging times are based on 50% discharged full size vehicle/truck car battery.

Results may vary due to temperature, age of battery or other factors.



Related Products...
9420 20 Amp 12 Volt Charger With Intellamatic III
Price $294.95
Add
Associated 9420 20 Amp 12 Volt Charger With Intellamatic III
9410 10 Amp 12 Volt Charger With Intellamatic III
Price $218.95
Add
Associated 9410 10 Amp 12 Volt Charger With Intellamatic III
6003 70/250 Amp 12 Volt Charger Intellamatic Pro
Price $787.95
Add
Associated 6003 70/250 Amp 12 Volt Charger W/ Intellamatic Pro
VEC1095A 25/10/2/75 12 Volt Battery Charger
Price $76.34
Add
VEC1095A Vector 25/10/2/75 Amp 12 Volt Battery Charger/Starter/Tester/Conditioner
VEC1097A 30/10/2/80 12 Volt Battery Charger
Price $78.95
Add
VEC1097A Vector 30/10/2/80 Amp 12 Volt With Start Battery Charger/Starter/Tester/Conditioner
Century Tool And Equipment
4533 Towne Court
St. Charles MO 63304
 About Us
 Become an Affiliate
 Privacy Policy
 Send Us Feedback