Power Probe™ III 12 to 42-Volt Lead Tester with Case and Accessories.
When you connect your Power Probe to the car battery you will have a multitude of testers at your finger tips. With the press of a switch you'll have an instant hot lead or ground lead. Use the hot and ground lead simultaneously to activate components right in your hand. Instantly check components for continuity as well as identify positive, negative and open circuits without re-polarizing hook-up clips. Follow and locate shorts without wasting fuses. The 19ft lead will allow you to test bumper to bumper without jumper leads.
Power Probe IIIMaximum Voltage on Probe Tip: ± 200 Volts Relative to the Negative Battery Clip Probe tip resistance to ground 130KΩ Computer Safe: 0.1mA floating tip(warning: do not press power switch while connected to computer circuits with PP1,2 or 3)
Power Probe Mode (Mode 1)DC Voltage Measurement: 0 to 70 Volts (in 1/10th increments) AC Voltage Measurement: 0 to 70 Volts Peak to Peak (See Peak to Peak & Threshold Setting Mode 5)
Square Wave Input Response: 15 Hz to over 500KHz Sine Wave Input Response: 35 Hz to over 250KHz
Continuity to Ground: Greater than 20K Ohms - Display is Blank Less than 20K Ohms: Display reads 0.0 Less than 2K Ohms: Display reads 0.0 and Green Led is On
Min (Mode 2) & Max (Mode 3)Voltage Measurement: 0 to 70 Volts
Single Event Capture: Less than 200 Micro Second Pulse Width
Repetitive Events: Less than 1 Micro Second Pulse Width
Peak to Peak Mode (Mode 4)
0 to 70 Volts P-P Square Wave
Input Response: 4 Hz to over 500KHz
Sine Wave Input Response: 4 Hz to over 250KHz
Peak
to Peak Mode Threshold Setting (Mode 5)
0.2, 0.5, 1, 2, 5, 10 & 50 When the Peak to Peak Voltage on the Probe Tip exceeds this threshold then the display is Peak to Peak AC rather than DC.
Storage temperature: -40°C (-40°F) to 70°C (158°F)
Operating temperature -20°C (-4°F) to 60°C (140°F)
Circuit Breaker 8 amp thermal response - manual reset 8 amp=No trip 10 amps=20 min. 15 amps=6 sec. 25 amps=2 sec. Short circuit=0.3 sec.