Product Features
- Large display with backlight
- Insulation test : 0.01 M? to 2 G? Insulation test voltages for many applications: 50 V, 100 V, 250 V, 500 V, 1000 V
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (?), Continuity
-
Capacitance, diode test, temperature, Min/Max, frequency (Hz)
Insulation Multimeter Includes:
- Remote probe
- Test leads
- Alligator clips
- K-type thermocouple
- Hard case
- Four AA alkaline batteries
- Quick Reference Guide
- CD Rom with Manual
Features |
1587 |
1577 |
Insulation test voltages 50V, 100V, 250V, 500V, 1000V |
• |
|
Insulation test voltages 500V, 1000V |
|
• |
Insulation test: 0.01 MÙ to 2.0 GÙ |
• |
|
Insulation test: 0.1 MÙ to 600 MÙ |
|
• |
Auto discharge of capacitive voltage |
• |
• |
Insulation test smoothing reading |
• |
|
Frequency |
• |
|
Capacitance |
• |
|
Diode test |
• |
|
Temperature |
• |
|
Min/Max |
• |
|
Low pass filter (for work on VSD's) |
• |
|
AC/DC Voltage |
• |
• |
DC millivolts |
• |
• |
AC/DC milliamps |
• |
• |
Resistance (0.1 Ù to 50 MÙ) |
• |
• |
Continuity |
• |
• |
Three-year warranty |
• |
• |
Remote probe, test leads, alligator clips |
• |
• |
K-type thermocouple |
• |
|
Rugged, utility hard case |
• |
• |
Auto power off to save battery power |
• |
• |
True-rms |
• |
• |
Large display with backlight |
• |
• |
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection |
• |
• |
CAT III 100V, CAT IV 600V measurement category |
• |
• |
Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work |
• |
• |
Specifications |
Voltage DC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(0.2%+2) |
|
1587: ±(0.09%+2) |
Maximum Resolution: |
0.001V | |
Voltage AC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(2%+3) |
|
1587: ±(2%+3) |
AC Bandwidth: |
1587: 5kHz* |
|
*with low pass filter; 3db @ 800 Hz |
Maximum Resolution: |
0.1 mV | |
Current DC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(1.0%+2) |
|
1587: ±(0.2%+2) |
Maximum Resolution: |
0.01 mA | |
Current AC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(2.0%+2)* |
|
1587: ±(1.5%+2)* |
|
* 1kHz bandwidth |
Maximum Resolution: |
0.01 mA | |
Resistance |
Maximum Resistance: |
50 MÙ |
Accuracy: |
1577: ±(1.2%+2) |
|
1587: ±(0.9%+2) |
Maximum Resolution: |
0.1Ù | |
Capacitance(1587 only) |
Maximum Capacitance: |
9,999 µF |
Accuracy: |
±(1.2%+2) |
Maximum Resolution: |
1 nF | |
Frequency (1587 only) |
Maximum Frequency: |
100 kHz |
Accuracy: |
±(0.1%+1) |
Maximum Resolution: |
0.01 Hz | |
Temperature Measurement (1587 only) |
|
-40.0 °C to 537 °C |
|
-40.0 °F to 998 °F |
|
excluding probe | |
Diode Test (1587 only) |
Range: |
6 V |
Resolution: |
1 mV |
Accuracy: |
±(2 % + 1) | |
Insulation Test |
Minimum Test Current @ 1kÙ/V: |
|
Test Voltages: |
1577: |
500, 1000 V |
1587: |
50, 100, 250, 500, 1000 V | |
Maximum Resistance per Test Voltage: |
50V: |
|
100V: |
|
250V: |
|
500V: |
|
1000V: |
1577: 600 MÙ |
|
1587: 2 GÙ | |
Maximum Resolution per Test Voltage: |
50V: |
0.01 MÙ |
100V: |
0.01 MÙ |
250V: |
0.1 MÙ |
500V: |
0.1 MÙ |
1000V: |
0.1 MÙ | |
Accuracy per Test Voltage: |
50V: |
±(3 % + 5) |
100V: |
±(3 % + 5) |
250V: |
±(1.5 % + 5) |
500V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) |
1000V: |
1577: ±(2.0 % + 5) |
|
1587: ±(1.5 % + 5) to 600 MÙ, ±(10 % + 3) above 600 MÙ | |
Environmental Specifications |
Operating temperature |
|
Storage temperature |
|
Humidity (Without Condensation) |
|
0% - 95% (10 °C – 30 °C) |
|
0% - 75% (30 °C – 40 °C) |
|
0% - 40% (40 °C – 55 °C) | |
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V | |
Agency Approvals |
|
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V | |
Mechanical & General Specifications |
Size |
|
203 x 100 x 50 mm (with holster) | |
Weight |
|
Warranty |
|
Battery life Alkaline |
Meter use: |
1000 hours |
Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MÙ with a duty cycle of 5 seconds on and 25 seconds off. | |
IP Rating |
|
|
|
|
|
|
|
|